Factory hours · Mon–Fri 8:30–17:30 · Sat 8:30–12:30 · Fast quotes online
3-in-1 Certified EngineeringBS EN 13030 · ASTM E90

Architectural Performance & Acoustic Louvres

Stop the rain. Move the air. Soothe the noise. Singapore's first 3-in-1 architectural louvre systems certified for heavy wind-driven rain defence, high aerodynamic airflow, and acoustic attenuation.

BSRIA (UK) BS EN 13030 Rain Tested
Riverbank (US) ASTM E90 Acoustic Certified
Singapore Factory Custom Fabrication
WSS Architectural Performance Louvres Installed on Singapore Commercial Building Facade
3-in-1 Triple ActionWind-Driven Rain Defence · High Aerodynamic Ventilation · Acoustic Dampening
100% Class A Available
The 3-in-1 Engineering Standard

Where There's Airflow, There Can Be Rain & Noise.

Traditional louvres were built only for airflow and screening, leaving buildings vulnerable to monsoonal water ingression and equipment noise pollution. WSS bridges all three disciplines in a single tested system.

Pillar 01 · Weather Tightness

Stop the Rain

Tested to BS EN 13030:2001 by BSRIA (UK) under simulated torrential rain of 75 mm/hr at 13 m/s wind speed across core velocities from 0 to 3.5 m/s.

Class A Rating:99% to 100% water rejection (≤ 0.75 l/h/m² penetration).
Pillar 02 · Aerodynamic Efficiency

Move the Air

Streamlined blade geometries engineer low entry and discharge loss coefficients. High free area lowers mechanical fan pressure drop, reducing HVAC power consumption.

Class 1 Discharge: Up to 0.466 discharge coefficient for passive intake and exhaust.
Pillar 03 · Acoustic Mitigation

Soothe the Noise

Tested and certified to ASTM E90-09(2016) by Riverbank Acoustical Laboratories (US). Certified sound transmission loss across 1/3 octave bands from 63 Hz to 8 kHz.

STC 15 · Up to 31 dB: Attenuation for cooling towers, chillers, and substations.
Commercial & Industrial ApplicationsStrictly Commercial · Not for Residential Homes

Where Engineering Demands Outgrow Domestic Windows

Performance and acoustic louvres sit at the critical intersection of high-volume airflow, storm weather defence, and municipal noise limits. Unlike residential domestic windows, these systems are engineered to protect critical infrastructure, heavy plant rooms, and landmark building envelopes.

Commercial & Industrial Specification Notice

WSS Performance & Acoustic Louvres are custom-fabricated for high-CFM mechanical ventilation, electrical substations, and architectural facades. They are not designed for residential domestic window installations. For HDB, condominium, or landed home residential windows, please explore our Residential Louvre Windows.

Mission-Critical Infrastructure

Data Centres & Server Halls

Hyperscale and enterprise colocation facilities require massive airflow volumes (CFM) for free cooling economizer cycles while guaranteeing zero water ingress into UPS battery rooms and switchgear galleries.

  • Class A Rain Rejection: Prevents electrical shorts during tropical monsoon downpours.
  • Low Pressure Drop: Meets strict PUE targets under BCA-IMDA Green Mark for Data Centres (GM:DC).
  • Generator Noise Barrier: ACL-300S dampens emergency standby diesel generator roar.
Recommended: MPL-250V · ACL-300S
Power & Utilities

SP Group Electrical Substations

66kV, 22kV, and consumer substations rely on natural convective cooling for oil-filled and dry-type transformers generating continuous passive heat, without mechanical fan failure risk.

  • 100% Class A at 3.5 m/s: Vertical double-bank MPL-250V eliminates wind-driven water ingress.
  • Anti-Intrusion & Vermin Mesh: Stainless steel bird and insect screening prevents transformer arc flashovers.
  • Zero Power Passive Flow: High free area supports continuous thermal chimney convection.
Recommended: MPL-250V · MPL-250
Acoustic & Mechanical Plant

Chiller Enclosures & Plant Rooms

Central cooling towers, water-cooled chillers, and air handling units (AHUs) require unrestricted intake and exhaust while curbing mechanical hums across building property boundaries.

  • NEA Boundary Noise Compliance: Meets Singapore EPMC limits (50–55 dBA night residential / 60 dBA noise-sensitive).
  • Tested Sound Transmission Loss: ASTM E90 certified up to 31 dB attenuation across octave bands 63 Hz–8 kHz.
  • Tropicalized Media: Non-hygroscopic acoustic infill with erosion-resistant tissue facing for 90%+ humidity.
Recommended: ACL-300S · ACL-150S
Commercial Architecture

Continuous Architectural Façades

Commercial high-rises and landmark office towers demand sleek, unbroken horizontal or vertical lines that camouflage mechanical floors without aerodynamic compromise.

  • Hidden Mullion Aesthetics: APL series continuous blade lines conceal vertical structural supports.
  • BCA Green Mark (GM:2021): Class 1 discharge coefficient reduces HVAC fan energy consumption.
  • SCDF Smoke Purge Compliance: Verified aerodynamic free area for certified engineered emergency exhaust.
Recommended: APL-175 · APL-275
Healthcare & Public Infrastructure

Hospitals & Transit Compounds

Clinical hospital campuses (such as Woodlands Health Campus) and subterranean MRT transit hubs mandate whisper-quiet operation and fail-safe weather protection.

  • Acoustic Isolation for Healing: Eliminates low-frequency mechanical drone near patient wards.
  • Carpark & Shaft Ventilation: Passive carbon monoxide dissipation with storm-proof rain defence.
  • AAMA 2605 PVDF Coating: Resists tropical acid rain, high UV radiation, and maritime salt spray.
Recommended: ACL-300S · APL-275 · VPL-250
Custom Engineering Support

Need Calculations for Tender Submission?

Our in-house technical engineers calculate airflow face velocities, static pressure drops (Pa), and required insertion loss (dB) based on your mechanical drawings.

CAD / Revit DWG Elevation & Section details
BSRIA & Riverbank 3rd-party laboratory test sheets
Singapore factory direct fabrication schedule
System Families & Engineering Matrix

Engineered Configurations for Every Façade & Plant Room

Choose from continuous Hidden Mullion screening, modular Visible Mullion assemblies, or high-performance Acoustic sound-dampening louvres. All systems are custom-fabricated to project schedules at our Singapore manufacturing base.

View:
Hidden Mullion120mm depth · 75mm pitch

APL-175

Horizontal Single Bank

Rain Defense (BSRIA):Class D
Airflow Coeff:0.466 (Class 1 (Excellent))
Acoustic Rating:STC 1 · 17 dB
Optimal Application:

Maximum passive air intake & exhaust in sheltered areas

Hidden Mullion142mm depth · 75mm pitch

APL-275

Horizontal Double Bank

Rain Defense (BSRIA):Class A (0–0.5 m/s), Class B (1–2 m/s)
Airflow Coeff:0.292 (Class 3 (Good))
Acoustic Rating:STC 2 · 20 dB
Optimal Application:

Commercial building facade screening with balanced weather protection

Hidden Mullion142mm depth · 75mm pitch

APL-375

Horizontal Triple Bank

Rain Defense (BSRIA):Class A (0–2.0 m/s), Class B (2.5–3.0 m/s)
Airflow Coeff:0.174 (Class 4 (Fair))
Acoustic Rating:STC 2 · 21 dB
Optimal Application:

Unsheltered continuous facade screening against tropical monsoons

Visible Mullion72mm depth · 75mm pitch

MPL-175

Horizontal Single Bank

Rain Defense (BSRIA):Class D
Airflow Coeff:0.466 (Class 1 (Excellent))
Acoustic Rating:STC 1 · 17 dB
Optimal Application:

Slimline modular ventilation screens for non-weather-exposed walls

Visible Mullion129mm depth · 50mm pitch

MPL-250

Horizontal Double Bank

Rain Defense (BSRIA):Class A (0–2.0 m/s), Class B (2.5–3.5 m/s)
Airflow Coeff:0.325 (Class 2 (Very Good))
Acoustic Rating:STC 2 · 22 dB
Optimal Application:

High airflow with heavy rain resistance for M&E plant enclosures

Flagship Spec
Visible Mullion129mm depth · 50mm pitch

MPL-250V

Vertical Double Bank

Rain Defense (BSRIA):Class A Across All Speeds (0–3.5 m/s)
Airflow Coeff:0.326 (Class 2 (Very Good))
Acoustic Rating:STC 2 · 22 dB
Optimal Application:

Maximum severe weather defense: zero water penetration at any face velocity

Visible Mullion72mm depth · 50mm pitch

VPL-250

Vertical Double Bank (Slim)

Rain Defense (BSRIA):Class A (0–2.0 m/s), Class B (2.5 m/s)
Airflow Coeff:0.181 (Class 4 (Fair))
Acoustic Rating:STC 2 · 20 dB
Optimal Application:

Compact-depth vertical louver for shallow architectural reveals

Visible Mullion102mm depth · 70mm pitch

MPL-270

Horizontal Double Bank

Rain Defense (BSRIA):Class A (0–0.5 m/s), Class B (1–1.5 m/s)
Airflow Coeff:0.180 (Class 4 (Fair))
Acoustic Rating:STC 2 · 22 dB
Optimal Application:

Medium-depth horizontal screening for plant room louvres

Acoustic Louver150mm depth · 250mm pitch

ACL-150S

Horizontal Single Blade Acoustic

Rain Defense (BSRIA):Class C (0 m/s), Class D (0.5+ m/s)
Airflow Coeff:0.176 (Class 4 (Fair))
Acoustic Rating:STC 11 · 24 dB @ 8kHz (19 dB @ 1kHz)
Optimal Application:

Car parks, ventilation shafts, and general mechanical noise damping

Flagship Spec
Acoustic Louver300mm depth · 300mm pitch

ACL-300S

Horizontal Double Blade Acoustic

Rain Defense (BSRIA):Class C (0 m/s), Class D (0.5+ m/s)
Airflow Coeff:0.151 (Class 4 (Fair))
Acoustic Rating:STC 15 · 31 dB @ 8kHz (25 dB @ 1kHz)
Optimal Application:

Heavy plant rooms, cooling towers, chillers, and NEA boundary compliance

Independent Laboratory Rigour

Tested to Leading International Standards in the UK and US

All WSS louvres are rigorously evaluated by stringent 3rd-party accredited laboratories to validate rain rejection, airflow efficiency, and sound transmission loss.

BSRIA Laboratories · UKBS EN 13030:2001

Simulated Wind-Driven Rain Test Chamber

Evaluates water rejection performance when subjected to simultaneously simulated torrential rainfall of 75 mm/hr and wind speeds of 13 m/s across 8 distinct core velocities (0 to 3.5 m/s).

BS EN 13030 Rain Test Chamber Schematic by BSRIA Laboratories
BS EN 13030 Rain Defence Classification
Class A (WSS Standard)99% to 100% Water Rejection (≤ 0.75 l/h/m²)
Class B95% to 98% Water Rejection (3.75 l/h/m²)
Class C80% to 94% Water Rejection (15.00 l/h/m²)
Class DBelow 80% (> 15.00 l/h/m²)
Riverbank Acoustical Labs · USASTM E90-09(2016)

Dual Reverberation Sound Transmission

Laboratory measurement of airborne sound transmission loss between two adjacent reverberation chambers. Determines Sound Transmission Class (STC) and Outdoor-Indoor Transmission Class (OITC) to ASTM E413 and ASTM E1332.

ASTM E90 Acoustic Measurement Procedure Schematic
ASTM E90 Sound Transmission Loss Breakdown
ACL-300S Heavy Double BladeSTC 15 · Noise Reduction up to 31 dB
ACL-150S Single Blade AcousticSTC 11 · Noise Reduction up to 24 dB
APL / MPL Standard PerformanceSTC 1–2 · Noise Reduction up to 22 dB
Frequency Octave Band Range63 Hz to 8,000 Hz Full Spectrum Tested
Engineering Checklist

How to Specify the Right Louvre System

Selecting the optimal louvre configuration requires balancing acoustic damping, allowable water ingression, and required airflow pressure drops. Our facade engineers evaluate:

Project Site Location
Wind zone exposure and building elevation.
Weather Exposure
Degree of acceptable water penetration.
Behind-Louvre Use
Equipment room, car park, or conditioned plenum.
Airflow & Pressure Drop
Design m³/s velocity and allowable Pa loss.
Acoustic Targets
NEA boundary noise limit and dBA attenuation.
Façade Integration
Hidden continuous lines vs modular panels.
Surface Protection

Architectural Protective Finishes

To withstand Singapore’s tropical UV radiation, humidity, and maritime coastal atmosphere, all louvre systems are available with high-performance surface coatings:

Fluorocarbon PVDF Finish

2, 3 or 4 Coat Systems

Premium architectural coating compliant with AAMA 2605. Exceptional chalking and color retention resistant to intense tropical sun and acid rain. Over 20-year exterior life.

Polyester Powder Coating (PPC)

Qualicoat Standard

High-durability polyester powder finish available in the complete RAL color library with smooth, matte, textured, or metallic effects.

Architectural Anodising

15 to 25 Micron Grades

Electro-chemically bonded aluminum oxide coating providing authentic metallic sheen in natural clear, champagne, bronze, and black.

Project Reference Gallery

Real Built Installations in Singapore

Supplying precision architectural facade louvres and mechanical plant room enclosures across commercial landmarks, data facilities, and healthcare campuses.

Continuous architectural performance louvre facade corner detail
Commercial Building Facade · Hidden Mullion System
Architectural louvre screening for plant room and electrical substation
Electrical Substation · High-Airflow Weather Screening
Modern horizontal architectural performance louvre wall facade
Industrial Plant Enclosure · Visible Mullion System
Horizontal commercial louvre facade bands against sky
Architectural Screening · Continuous Louvre Bands
Technical Q&A

Frequently Asked Engineering Questions

Detailed guidance for architects, MEP consultants, and main contractors specifying louvres in Singapore.

Q1.What makes WSS 3-in-1 Performance Louvres different from standard louvres?

Conventional louvres only provide visual screening with untested airflow resistance and water leakage risks. WSS Performance Louvres are engineered and tested in accredited 3rd-party laboratories: BSRIA in the UK for simulated hurricane-force wind-driven rain (BS EN 13030:2001) and Riverbank in the US for acoustic sound transmission loss (ASTM E90-09). They guarantee certified weather protection, aerodynamic airflow, and noise mitigation in a single facade package.

Q2.Which louver model delivers the highest rain protection vs airflow rate?

For zero rain penetration in exposed facades, model MPL-250V (vertical double bank) achieves 100% Class A rain defence across all tested core velocities from 0 to 3.5 m/s. For high-volume air intake/exhaust where weather exposure is sheltered, single-bank models (APL-175, MPL-175) deliver Class 1 discharge coefficients (0.466). For plant rooms and equipment enclosures, double-bank models (APL-275, MPL-250) provide the optimal balance.

Q3.When should Acoustic Louvres (ACL series) be specified?

ACL series acoustic louvres (ACL-150S single blade and ACL-300S double blade) incorporate perforated acoustic infill tested to achieve up to 31 dB noise reduction index and STC 15. They are specified for cooling towers, chiller plants, emergency generators, transformer substations, and carparks where mechanical equipment noise must meet Singapore NEA boundary noise limits while maintaining required ventilation volume.

Q4.Can WSS supply custom blade pitches, curved profiles, and PVDF coatings to tender specs?

Yes. All systems are fabricated in our 22,000 sq ft Singapore facility at 11 Senoko Drive. We fabricate custom mullion depths, continuous hidden mullion runs, curved or straight front blade aesthetics, and project-specific finishes including Qualicoat polyester powder coating, architectural anodising, and 2/3/4-coat PVDF architectural finishes to any RAL or master colour code.

Q5.How do architects, MEP consultants, and main contractors submit RFQs and tender drawings?

Architects and main contractors can submit architectural elevation drawings, M&E airflow/pressure drop requirements, and acoustic target schedules directly to info@wss.com.sg or via our WhatsApp engineering line at +65 8758 3131. Our technical facade team reviews airflow calculations and provides compliant shop drawings, test reports, and tender quotations.

Direct Singapore Manufacturer · 45 Years of Heritage

Submit Your Architectural Drawings & Schedules

Our technical engineering team reviews airflow calculations, pressure drop limits, and acoustic specifications to deliver fully compliant shop drawings, test reports, and tender pricing.

Factory: 11 Senoko Drive, Singapore 758199Tel: +65 8758 3131Email: info@wss.com.sgCustom Fabrication to Project Schedule
Drop us a message.